An ISO 9001:2015 certified company

Cooling Tower Antiscalant

Price 65 INR/ Kilograms
MOQ : 100 Kilograms

Cooling Tower Antiscalant

COOLING TOWER ANTISCALANT Specification

Packaging Type CARBOYS
Shelf Life 12 Months
Storage DO NOT SUNLIGHT
Solubility WATER SOLUBLE
CAS No 5542254
Chemical Name Other
Physical Form Liquid
Grade Industrial Grade
Purity(%) 100
Type Other
Application Other

About COOLING TOWER ANTISCALANT

Description:

  • Antiscalant effectively controls scales and fouling in cooling system
  • Compatible with all of the leading Chemicals
  • Effective over a wide pH range.
  • Decreases frequent shutdowns, periodical cleaning and servicing of the system.
  • Reduces extra energy, manpower, expenses and forcefully untimely-allotted time.

Features:

  • Effective usage
  • Enhanced shelf life
  • Uniform composition

COOLING TOWER ANTISCALANT Trade Information

Minimum Order Quantity 100 Kilograms
FOB Port NO
Payment Terms Others
Supply Ability 100000 Kilograms Per Week
Delivery Time 2 Days
Sample Available No
Sample Policy Free samples available with shipping and taxes paid by the buyer
Packaging Details 50 KGS CARBOYS
Main Export Market(s) Asia
Main Domestic Market All India
Certifications ISO-GMP

Cooling Tower Antiscalant Manufacturer & Supplier in India

High-Efficiency Scale Inhibition for Industrial Recirculating Systems

Industrial refrigeration systems must constantly transfer heat to the production area. Minerals can clog up cooling towers, causing them to perform badly. Aries Chemical’s products protect heat exchangers from intense precipitation so they perform at their best. We are a leading cooling tower chemical manufacturer and offer special formulations that are designed to combat difficult water conditions encountered in the manufacturing industry.

Our cooling tower antiscalant prevents the buildup of hard water salts in open recirculating systems. Without chemical intervention, heat exchangers become densely covered with thick insulating material, clogging the system, increasing energy costs, and producing localised under-deposit corrosion. With our polymer dispersing technology, we hold potentially damaging mineral particles through cooling water antiscalant suspended in the recirculating water loop for easy blowdown and extended equipment life.

Why Scaling Happens in Recirculating Cooling Towers

Scaling is an issue in open recirculating cooling systems because of evaporative cooling. As pure water evaporates into the atmosphere, solids remain and become more concentrated until water reaches saturation and minerals precipitate out of solution and stick to hot metal surfaces.

Top contributors to thermal inefficiency include:

How Aries Cooling Tower Antiscalant Works

Our advanced cooling water treatment chemicals work in several ways to disrupt mineral precipitation. First, they inhibit thresholds, which significantly increase the solubility limit of hard water salts, making them dissolvable well past the saturation point. Second, a crystal modification chemical twists the structure of forming crystals, making them asymmetrical and unable to adhere to metallic surfaces. Third, high-charge dispersants keep suspended particles separate, enabling clean airflow of the suspended particles following every blowdown.

This cooling tower scale reduction chemical is extremely stable between 6.5 and 9.5 pH, eliminating the risk of acid dosing to control pH. Use of this tower scale prevention chemical has several benefits for the plant: 

  • Maximises heat transfer by keeping heat exchanger tubes free of mineral deposits; 
  • Increases the number of production runs between maintenance by reducing the number of cleanings; 
  • Increases water use by operating the system at higher cycles of concentration (COC).

Technical Specifications

The technical datasheet below describes typical physical properties of our standard formulation. Refer to the system specifications outlined in this quick-reference spec sheet:

Parameter

Specification

Appearance

Clear to Light Amber Liquid

Specific Gravity

1.15 ± 0.05

pH (as is)

2.0 – 4.0

Solubility

Completely Soluble in Water

Active Content

Proprietary Phosphonocarboxylate & Polymetric Blend

Recommended Dosage & System Compatibility

As water quality and other operating parameters can vary greatly across different facilities, chemical treatment has to be precise. The cooling tower antiscalant chemical is injected either continuously into the makeup water line or directly into the cooling tower basin at a dose of 5 to 25 ppm (parts per million). The correct amount depends on your water’s hardness, silica content, temperature of the skin, and Cycles of Concentration.

Aries chemicals are chemically compatible with most other industrial cooling tower chemicals. They are chemically compatible with chlorine and bromine-based oxidizing biocides and non-oxidizing biocides, as well as being resistant to halogens. This is good news for your microbiology control programs because it will not affect your scale and corrosion protection. For optimal water management, we offer solutions for RO Antiscalant Chemicals to maintain auxiliary water treatment chemicals.

Applications & Industries Served

Our water treatment systems are used to protect cooling towers. As a antiscalant chemical supplier, Aries Chemical serves many industries where the rate of thermal efficiency is critical to the profit margin: 

  • Power Generation & Petrochemicals: Safeguarding massive surface condensers and high-temperature process loops.
  • Textile Processing & Chemical Manufacturing: Preventing heat exchanger fouling in highly demanding process environments.
  • Pharmaceuticals & FMCG: Maintaining precise temperature controls in sterile production zones.
  • HVAC Systems: Optimising commercial comfort cooling loops and chiller configurations across corporate infrastructure.
 

For optimal utility plant protection, check out our range of COOLING TOWER Chemicals.

Why Choose Aries Chemical

Aries Chemical is an ISO 9001:2015 certified manufacturer of industrial engineering plastics. Located in Vadodara, Gujarat, our modern production plant houses cutting edge polymer chemistry with quality assurance processes that ensure consistency from batch to batch.

We understand downtime is costly. With a strong supply chain and distribution network, we can provide prompt delivery across India. We deliver on a 2-day delivery commitment to major industrial centres. You will never face a chemical stockout in your plant. We cover all aspects of the water lifecycle—from preventative scaling to regular maintenance such as Descaling Chemical for fouled pipes.

To learn more about our engineering solutions for open and closed loops, visit the Cooling Tower Chemicals main page.

Protect Your Cooling Infrastructure Today

Don’t let mineral scale impact your production or lead to a spike in your electricity bills. Contact the most reliable cooling tower antiscalant manufacturer India has to offer.

Request a free water analysis or get a quote from our engineering team in Vadodara today.

FAQs of Cooling Tower Antiscalant:

What is Cooling Tower Antiscalant and how does it work?

It is a chemical compound used in cooling tower water treatment to prevent mineral deposits from forming on heat transfer surfaces. It works by inhibiting the threshold, by distorting crystal lattices, and by dispersing scale-forming ions so they can be safely suspended in the water column and blowdown.

Our advanced antiscalant for open recirculating cooling tower is a multi-polymer blend that is formulated to prevent the formation of calcium carbonate, calcium sulphate, barium sulphate, and low-to-moderate levels of reactive silica.

Depending upon the hardness of the water, skin temperature, and the operating COC, the average dose is 5 to 25 ppm. Aries Chemical provides custom dosing charts based on the analysis of the water in your system.

Yes. Our antiscalant formulations are chemically inert when diluted with common water treatment additives such as zinc or phosphate-based corrosion inhibitors and oxidising biocides such as chlorine.

Our chemicals have a shelf life of 12 months when stored in their original, unopened UV-stabilised containers. Drums should be stored in cool, dry, well-ventilated storage areas away from direct sunlight and incompatible materials.

Cooling Tower Antiscalant Chemical is supplied in liquid form.

Cooling Tower Antiscalant Chemical is supplied in liquid form.

Cooling Tower Antiscalant Chemical is easily soluble in water.

Cooling Tower Antiscalant Chemical should be stored at room temperature.

Cooling Tower Antiscalant Chemical has a purity level of 99%.

Interested in this product?

Get high-performance, cost-effective Consumable Chemicals backed by expert technical support and on-time delivery.

Tell us about your requirement